CVE编号
CVE-2019-10935利用情况
暂无补丁情况
N/A披露时间
2019-07-12漏洞描述
A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions < V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1 with WinCC V7.4 SP1 Upd 11), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC Professional (TIA Portal V13) (All versions), SIMATIC WinCC Professional (TIA Portal V14) (All versions < V14 SP1 Upd 9), SIMATIC WinCC Professional (TIA Portal V15) (All versions < V15.1 Upd 3), SIMATIC WinCC Runtime Professional V13 (All versions), SIMATIC WinCC Runtime Professional V14 (All versions < V14.1 Upd 8), SIMATIC WinCC Runtime Professional V15 (All versions < V15.1 Upd 3), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 (All versions < V7.3 Upd 19), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Upd 11), SIMATIC WinCC V7.5 (All versions < V7.5 Upd 3). The SIMATIC WinCC DataMonitor web application of the affected products allows to upload arbitrary ASPX code. The security vulnerability could be exploited by an authenticated attacker with network access to the WinCC DataMonitor application. No user interaction is required to exploit this vulnerability. The vulnerability impacts confidentiality, integrity, and availability of the affected device. At the stage of publishing this security advisory no public exploitation is known.解决建议
建议您更新当前系统或软件至最新版,完成漏洞的修复。
参考链接 |
|
---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-121293.pdf |
受影响软件情况
# | 类型 | 厂商 | 产品 | 版本 | 影响面 | ||||
1 | |||||||||
---|---|---|---|---|---|---|---|---|---|
运行在以下环境 | |||||||||
应用 | siemens | simatic_pcs_7 | 8.0 | - | |||||
运行在以下环境 | |||||||||
应用 | siemens | simatic_pcs_7 | 8.1 | - | |||||
运行在以下环境 | |||||||||
应用 | siemens | simatic_pcs_7 | 8.2 | - | |||||
运行在以下环境 | |||||||||
应用 | siemens | simatic_pcs_7 | 9.0 | - | |||||
运行在以下环境 | |||||||||
应用 | siemens | simatic_wincc | * |
Up to (including) 7.2 |
|||||
运行在以下环境 | |||||||||
应用 | siemens | simatic_wincc | 13 | - | |||||
运行在以下环境 | |||||||||
应用 | siemens | simatic_wincc | 14 | - | |||||
运行在以下环境 | |||||||||
应用 | siemens | simatic_wincc | 15 | - | |||||
运行在以下环境 | |||||||||
应用 | siemens | simatic_wincc | 7.3 | - | |||||
运行在以下环境 | |||||||||
应用 | siemens | simatic_wincc | 7.4 | - | |||||
运行在以下环境 | |||||||||
应用 | siemens | simatic_wincc | 7.5 | - | |||||
运行在以下环境 | |||||||||
应用 | siemens | simatic_wincc_runtime | 13 | - | |||||
运行在以下环境 | |||||||||
应用 | siemens | simatic_wincc_runtime | 14 | - | |||||
运行在以下环境 | |||||||||
应用 | siemens | simatic_wincc_runtime | 15 | - | |||||
运行在以下环境 | |||||||||
应用 | siemens | simatic_wincc_runtime | 15.1 | - |
- 攻击路径 网络
- 攻击复杂度 低
- 权限要求 高
- 影响范围 未更改
- 用户交互 无
- 可用性 高
- 保密性 高
- 完整性 高