CVE编号
CVE-2018-7112利用情况
暂无补丁情况
N/A披露时间
2018-12-04漏洞描述
The HPE-provided Windows firmware installer for certain Gen9, Gen8, G7,and G6 HPE servers allows local disclosure of privileged information. This issue was resolved in previously provided firmware updates as follows. The HPE Windows firmware installer was updated in the system ROM updates which also addressed the original Spectre/Meltdown set of vulnerabilities. At that time, the Windows firmware installer was also updated in the versions of HPE Integrated Lights-Out 2, 3, and 4 (iLO 2, 3, and 4) listed in the security bulletin. The updated HPE Windows firmware installer was released in the system ROM and HPE Integrated Lights-Out (iLO) releases documented in earlier HPE Security Bulletins: HPESBHF03805, HPESBHF03835, HPESBHF03831. Windows-based systems that have already been updated to the system ROM or iLO versions described in these security bulletins require no further action.解决建议
目前厂商已发布升级补丁以修复漏洞,补丁获取链接:https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US&docId=emr_na-hpesbhf03805en_us
参考链接 |
|
---|---|
http://www.securitytracker.com/id/1041984 | |
https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US&docId=emr_na-... | |
https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US&docId=emr_na-... | |
https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US&docId=emr_na-... | |
https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US&docId=emr_na-... |
受影响软件情况
# | 类型 | 厂商 | 产品 | 版本 | 影响面 | ||||
1 | |||||||||
---|---|---|---|---|---|---|---|---|---|
运行在以下环境 | |||||||||
系统 | hp | integrated_lights-out_2_firmware | * |
Up to (excluding) 2.33 |
|||||
运行在以下环境 | |||||||||
系统 | hp | integrated_lights-out_3_firmware | * |
Up to (excluding) 1.90 |
|||||
运行在以下环境 | |||||||||
系统 | hp | integrated_lights-out_4_firmware | * |
Up to (excluding) 2.60 |
|||||
运行在以下环境 | |||||||||
系统 | hp | proliant_bl280c_g6_server_bladefirmware | * |
Up to (excluding) 2018.05.21 |
|||||
运行在以下环境 | |||||||||
系统 | hp | proliant_bl2x220c_g6_server_blade_firmware | * |
Up to (excluding) 2018.05.21 |
|||||
运行在以下环境 | |||||||||
系统 | hp | proliant_bl2x220c_g7_server_blade_firmware | * |
Up to (excluding) 2018.05.21 |
|||||
运行在以下环境 | |||||||||
系统 | hp | proliant_bl420c_gen8_server_firmware | * |
Up to (excluding) 2018.01.22 |
|||||
运行在以下环境 | |||||||||
系统 | hp | proliant_bl460c_g6_server_blade_firmware | * |
Up to (excluding) 2018.05.21 |
|||||
运行在以下环境 | |||||||||
系统 | hp | proliant_bl460c_g7_server_blade_firmware | * |
Up to (excluding) 2018.05.21 |
|||||
运行在以下环境 | |||||||||
系统 | hp | proliant_bl460c_gen8_server_blade_firmware | * |
Up to (excluding) 2018.01.22 |
|||||
运行在以下环境 | |||||||||
系统 | hp | proliant_bl460c_gen9_server_blade_firmware | * |
Up to (excluding) 2.56_01-22-2018 |
|||||
运行在以下环境 | |||||||||
系统 | hp | proliant_bl465c_g7_server_blade_firmware | * |
Up to (excluding) 2018.03.14 |
|||||
运行在以下环境 | |||||||||
系统 | hp | proliant_bl465c_gen8_(amd)_firmware | * |
Up to (excluding) 2018.03.14 |
|||||
运行在以下环境 | |||||||||
系统 | hp | proliant_bl490c_g6_server_blade_firmware | * |
Up to (excluding) 2018.05.21 |
|||||
运行在以下环境 | |||||||||
系统 | hp | proliant_bl490c_g7_server_blade_firmware | * |
Up to (excluding) 2018.05.21 |
|||||
运行在以下环境 | |||||||||
系统 | hp | proliant_bl620c_g7_server_blade_firmware | * |
Up to (excluding) 2018.05.21 |
|||||
运行在以下环境 | |||||||||
系统 | hp | proliant_bl660c_gen8_server_blade_firmware | * |
Up to (excluding) 2018.01.22 |
|||||
运行在以下环境 | |||||||||
系统 | hp | proliant_bl660c_gen9_server_firmware | * |
Up to (excluding) 2.56_01-22-2018 |
|||||
运行在以下环境 | |||||||||
系统 | hp | proliant_bl680c_g7_server_blade_firmware | * |
Up to (excluding) 2018.05.21 |
|||||
运行在以下环境 | |||||||||
系统 | hp | proliant_bl685c_g7_server_blade_(amd)_firmware | * |
Up to (excluding) 2018.03.14 |
|||||
运行在以下环境 | |||||||||
系统 | hp | proliant_dl120_g6_server_firmware | * | - | |||||
运行在以下环境 | |||||||||
系统 | hp | proliant_dl120_g7_server_firmware | * |
Up to (excluding) 2018.05.21 |
|||||
运行在以下环境 | |||||||||
系统 | hp | proliant_dl120_gen9_server_firmware | * |
Up to (excluding) 2.56_01-22-2018 |
|||||
运行在以下环境 | |||||||||
系统 | hp | proliant_dl160_g6_server_firmware | * | - | |||||
运行在以下环境 | |||||||||
系统 | hp | proliant_dl160_gen8_server_firmware | * |
Up to (excluding) 2018.01.22 |
|||||
运行在以下环境 | |||||||||
系统 | hp | proliant_dl160_gen9_server_firmware | * |
Up to (excluding) 2.56_01-22-2018 |
|||||
运行在以下环境 | |||||||||
系统 | hp | proliant_dl170e_g6_server_firmware | * | - | |||||
运行在以下环境 | |||||||||
系统 | hp | proliant_dl170h_g6_server_firmware | * | - | |||||
运行在以下环境 | |||||||||
系统 | hp | proliant_dl180_g6_server_firmware | * | - | |||||
运行在以下环境 | |||||||||
系统 | hp | proliant_dl180_gen9_server_firmware | * |
Up to (excluding) 2.56_01-22-2018 |
|||||
运行在以下环境 | |||||||||
系统 | hp | proliant_dl20_gen9_server_firmware | * |
Up to (excluding) 2.56_01-22-2018 |
|||||
运行在以下环境 | |||||||||
系统 | hp | proliant_dl320e_gen8_server_firmware | * |
Up to (excluding) 2018.01.22 |
|||||
运行在以下环境 | |||||||||
系统 | hp | proliant_dl320e_gen8_v2_server_firmware | * |
Up to (excluding) 2018.01.22 |
|||||
运行在以下环境 | |||||||||
系统 | hp | proliant_dl320_g6_server_firmware | * |
Up to (excluding) 2018.05.21 |
|||||
运行在以下环境 | |||||||||
系统 | hp | proliant_dl360e_gen8_server_firmware | * |
Up to (excluding) 2018.01.22 |
|||||
运行在以下环境 | |||||||||
系统 | hp | proliant_dl360p_gen8_server_firmware | * |
Up to (excluding) 2018.01.22 |
|||||
运行在以下环境 | |||||||||
系统 | hp | proliant_dl360_g6_server_firmware | * |
Up to (excluding) 2018.05.21 |
|||||
运行在以下环境 | |||||||||
系统 | hp | proliant_dl360_g7_server_firmware | * |
Up to (excluding) 2018.05.21 |
|||||
运行在以下环境 | |||||||||
系统 | hp | proliant_dl360_gen9_server_firmware | * |
Up to (excluding) 2.56_01-22-2018 |
|||||
运行在以下环境 | |||||||||
系统 | hp | proliant_dl370_g6_server_firmware | * |
Up to (excluding) 2018.05.21 |
|||||
运行在以下环境 | |||||||||
系统 | hp | proliant_dl380e_gen8_server_firmware | * |
Up to (excluding) 2018.01.22 |
|||||
运行在以下环境 | |||||||||
系统 | hp | proliant_dl380p_gen8_server_firmware | * |
Up to (excluding) 2018.01.22 |
|||||
运行在以下环境 | |||||||||
系统 | hp | proliant_dl380_g6_server_firmware | * |
Up to (excluding) 2018.05.21 |
|||||
运行在以下环境 | |||||||||
系统 | hp | proliant_dl380_g7_server_firmware | - | - | |||||
运行在以下环境 | |||||||||
系统 | hp | proliant_dl380_gen9_server_firmware | * |
Up to (excluding) 2.56_01-22-2018 |
|||||
运行在以下环境 | |||||||||
系统 | hp | proliant_dl385p_gen8_(amd)_firmware | * |
Up to (excluding) 2018.03.14 |
|||||
运行在以下环境 | |||||||||
系统 | hp | proliant_dl385_g7_server_firmware | * |
Up to (excluding) 2018.03.14 |
|||||
运行在以下环境 | |||||||||
系统 | hp | proliant_dl560_gen8_server_firmware | * |
Up to (excluding) 2018.01.22 |
|||||
运行在以下环境 | |||||||||
系统 | hp | proliant_dl560_gen9_server_firmware | * |
Up to (excluding) 2.56_01-22-2018 |
|||||
运行在以下环境 | |||||||||
系统 | hp | proliant_dl580_g7_server_firmware | * |
Up to (excluding) 2018.05.21 |
|||||
运行在以下环境 | |||||||||
系统 | hp | proliant_dl580_gen8_server_firmware | * |
Up to (excluding) 2.00_02-22-2018 |
|||||
运行在以下环境 | |||||||||
系统 | hp | proliant_dl585_g7_server_(amd)_firmware | * |
Up to (excluding) 2018.03.14 |
|||||
运行在以下环境 | |||||||||
系统 | hp | proliant_dl60_gen9_server_firmware | * |
Up to (excluding) 2.56_01-22-2018 |
|||||
运行在以下环境 | |||||||||
系统 | hp | proliant_dl80_gen9_server_firmware | * |
Up to (excluding) 2.56_01-22-2018 |
|||||
运行在以下环境 | |||||||||
系统 | hp | proliant_dl980_g7_server_firmware | * |
Up to (excluding) 2018.05.21 |
|||||
运行在以下环境 | |||||||||
系统 | hp | proliant_m300_server_cartridge_firmware | * |
Up to (excluding) 2018.01.22 |
|||||
运行在以下环境 | |||||||||
系统 | hp | proliant_m350_server_cartridge_firmware | * |
Up to (excluding) 2018.01.22 |
|||||
运行在以下环境 | |||||||||
系统 | hp | proliant_m510_server_cartridge_firmware | * |
Up to (excluding) 1.64_01-22-2018 |
|||||
运行在以下环境 | |||||||||
系统 | hp | proliant_m710p_server_cartridge_firmware | * |
Up to (excluding) 2018.01.22 |
|||||
运行在以下环境 | |||||||||
系统 | hp | proliant_m710x_server_cartridge_firmware | * |
Up to (excluding) 1.64_01-22-2018 |
|||||
运行在以下环境 | |||||||||
系统 | hp | proliant_m710_server_cartridge_firmware | * |
Up to (excluding) 2018.01.22 |
|||||
运行在以下环境 | |||||||||
系统 | hp | proliant_microserver_gen8_firmware | * |
Up to (excluding) 2018.01.22 |
|||||
运行在以下环境 | |||||||||
系统 | hp | proliant_ml10_gen9_server_firmware | * |
Up to (excluding) 2018.01.22 |
|||||
运行在以下环境 | |||||||||
系统 | hp | proliant_ml10_v2_server_firmware | * |
Up to (excluding) 2018.01.22 |
|||||
运行在以下环境 | |||||||||
系统 | hp | proliant_ml110_g6_server_firmware | * | - | |||||
运行在以下环境 | |||||||||
系统 | hp | proliant_ml110_g7_server_firmware | * |
Up to (excluding) 2018.05.21 |
|||||
运行在以下环境 | |||||||||
系统 | hp | proliant_ml110_gen9_server_firmware | * |
Up to (excluding) 2.56_01-22-2018 |
|||||
运行在以下环境 | |||||||||
系统 | hp | proliant_ml150_g6_server_firmware | * | - | |||||
运行在以下环境 | |||||||||
系统 | hp | proliant_ml150_gen9_server_firmware | * |
Up to (excluding) 2.56_01-22-2018 |
|||||
运行在以下环境 | |||||||||
系统 | hp | proliant_ml30_gen9_server_firmware | * |
Up to (excluding) 2.56_01-22-2018 |
|||||
运行在以下环境 | |||||||||
系统 | hp | proliant_ml310e_gen8_server_firmware | * |
Up to (excluding) 2018.01.22 |
|||||
运行在以下环境 | |||||||||
系统 | hp | proliant_ml310e_gen8_v2_server_firmware | * |
Up to (excluding) 2018.01.22 |
|||||
运行在以下环境 | |||||||||
系统 | hp | proliant_ml330_g6_server_firmware | * |
Up to (excluding) 2018.05.21 |
|||||
运行在以下环境 | |||||||||
系统 | hp | proliant_ml350e_gen8_server_firmware | * |
Up to (excluding) 2018.01.22 |
|||||
运行在以下环境 | |||||||||
系统 | hp | proliant_ml350e_gen8_v2_server_firmware | * |
Up to (excluding) 2018.01.22 |
|||||
运行在以下环境 | |||||||||
系统 | hp | proliant_ml350p_gen8_server_firmware | * |
Up to (excluding) 2018.01.22 |
|||||
运行在以下环境 | |||||||||
系统 | hp | proliant_ml350_g6_server_firmware | * |
Up to (excluding) 2018.05.21 |
|||||
运行在以下环境 | |||||||||
系统 | hp | proliant_ml350_gen9_server_firmware | * |
Up to (excluding) 2.56_01-22-2018 |
|||||
运行在以下环境 | |||||||||
系统 | hp | proliant_ml370_g6_server_firmware | * |
Up to (excluding) 2018.05.21 |
|||||
运行在以下环境 | |||||||||
系统 | hp | proliant_sl160s_g6_server_firmware | * | - | |||||
运行在以下环境 | |||||||||
系统 | hp | proliant_sl170z_g6_server_firmware | * | - | |||||
运行在以下环境 | |||||||||
系统 | hp | proliant_sl210t_gen8_server_firmware | * |
Up to (excluding) 2018.01.22 |
|||||
运行在以下环境 | |||||||||
系统 | hp | proliant_sl250s_gen8_server_firmware | * |
Up to (excluding) 2018.01.22 |
|||||
运行在以下环境 | |||||||||
系统 | hp | proliant_sl270s_gen8_server_firmware | * |
Up to (excluding) 2018.01.22 |
|||||
运行在以下环境 | |||||||||
系统 | hp | proliant_sl2x170z_g6_server_firmware | * | - | |||||
运行在以下环境 | |||||||||
系统 | hp | proliant_sl390s_g7_server_firmware | * |
Up to (excluding) 2018.05.21 |
|||||
运行在以下环境 | |||||||||
系统 | hp | proliant_sl4540_gen8_1_node_server_firmware | * |
Up to (excluding) 2018.01.22 |
|||||
运行在以下环境 | |||||||||
系统 | hp | proliant_sl4545_g7_server_(amd)_firmware | 2018.03.14(a) | - | |||||
运行在以下环境 | |||||||||
系统 | hp | proliant_thin_micro_tm200_server_firmware | * |
Up to (excluding) 2.56_01-22-2018 |
|||||
运行在以下环境 | |||||||||
系统 | hp | proliant_ws460c_gen9_workstation_firmware | * |
Up to (excluding) 2.56_01-22-2018 |
|||||
运行在以下环境 | |||||||||
系统 | hp | proliant_xl170r_gen9_server_firmware | * |
Up to (excluding) 2.56_01-22-2018 |
|||||
运行在以下环境 | |||||||||
系统 | hp | proliant_xl190r_gen9_server_firmware | * |
Up to (excluding) 2.56_01-22-2018 |
|||||
运行在以下环境 | |||||||||
系统 | hp | proliant_xl230a_gen9_server_firmware | * |
Up to (excluding) 2.56_01-22-2018 |
|||||
运行在以下环境 | |||||||||
系统 | hp | proliant_xl250a_gen9_server_firmware | * |
Up to (excluding) 2.56_01-22-2018 |
|||||
运行在以下环境 | |||||||||
系统 | hp | proliant_xl260a_gen9_server_firmware | * |
Up to (excluding) 1.60_01-22-2018 |
|||||
运行在以下环境 | |||||||||
系统 | hp | proliant_xl270d_gen9_accelerator_tray_firmware | * |
Up to (excluding) 2.56_01-22-2018 |
|||||
运行在以下环境 | |||||||||
系统 | hp | proliant_xl270d_gen9_server_firmware | * |
Up to (excluding) 2.56_01-22-2018 |
|||||
运行在以下环境 | |||||||||
系统 | hp | proliant_xl450_gen9_server_firmware | * |
Up to (excluding) 2.56_01-22-2018 |
|||||
运行在以下环境 | |||||||||
系统 | hp | proliant_xl730f_gen9_server_firmware | * |
Up to (excluding) 2.56_01-22-2018 |
|||||
运行在以下环境 | |||||||||
系统 | hp | proliant_xl740f_gen9_server_firmware | * |
Up to (excluding) 2.56_01-22-2018 |
|||||
运行在以下环境 | |||||||||
系统 | hp | proliant_xl750f_gen9_server_firmware | * |
Up to (excluding) 2.56_01-22-2018 |
|||||
运行在以下环境 | |||||||||
硬件 | hp | integrated_lights-out | - | - | |||||
运行在以下环境 | |||||||||
硬件 | hp | integrated_lights-out_2 | - | - | |||||
运行在以下环境 | |||||||||
硬件 | hp | proliant_bl280c_g6_server | - | - | |||||
运行在以下环境 | |||||||||
硬件 | hp | proliant_bl2x220c_g6_server_blade | - | - | |||||
运行在以下环境 | |||||||||
硬件 | hp | proliant_bl2x220c_g7_server_blade | - | - | |||||
运行在以下环境 | |||||||||
硬件 | hp | proliant_bl420c_gen8_server | - | - | |||||
运行在以下环境 | |||||||||
硬件 | hp | proliant_bl460c_g6_server_blade | - | - | |||||
运行在以下环境 | |||||||||
硬件 | hp | proliant_bl460c_g7_server_blade | - | - | |||||
运行在以下环境 | |||||||||
硬件 | hp | proliant_bl460c_gen8_server_blade | - | - | |||||
运行在以下环境 | |||||||||
硬件 | hp | proliant_bl460c_gen9_server_blade | - | - | |||||
运行在以下环境 | |||||||||
硬件 | hp | proliant_bl465c_g7_server_blade | - | - | |||||
运行在以下环境 | |||||||||
硬件 | hp | proliant_bl465c_gen8_(amd) | - | - | |||||
运行在以下环境 | |||||||||
硬件 | hp | proliant_bl490c_g6_server_blade | - | - | |||||
运行在以下环境 | |||||||||
硬件 | hp | proliant_bl490c_g7_server_blade | - | - | |||||
运行在以下环境 | |||||||||
硬件 | hp | proliant_bl620c_g7_server_blade | - | - | |||||
运行在以下环境 | |||||||||
硬件 | hp | proliant_bl660c_gen8_server | - | - | |||||
运行在以下环境 | |||||||||
硬件 | hp | proliant_bl660c_gen9_server | - | - | |||||
运行在以下环境 | |||||||||
硬件 | hp | proliant_bl680c_g7_server_blade | - | - | |||||
运行在以下环境 | |||||||||
硬件 | hp | proliant_bl685c_g7_server_blade_(amd) | - | - | |||||
运行在以下环境 | |||||||||
硬件 | hp | proliant_dl120_g6_server | - | - | |||||
运行在以下环境 | |||||||||
硬件 | hp | proliant_dl120_g7_server | - | - | |||||
运行在以下环境 | |||||||||
硬件 | hp | proliant_dl120_gen9_server | - | - | |||||
运行在以下环境 | |||||||||
硬件 | hp | proliant_dl160_g6_server | - | - | |||||
运行在以下环境 | |||||||||
硬件 | hp | proliant_dl160_gen8_server | - | - | |||||
运行在以下环境 | |||||||||
硬件 | hp | proliant_dl160_gen9_server | - | - | |||||
运行在以下环境 | |||||||||
硬件 | hp | proliant_dl170e_g6_server | - | - | |||||
运行在以下环境 | |||||||||
硬件 | hp | proliant_dl170h_g6_server | - | - | |||||
运行在以下环境 | |||||||||
硬件 | hp | proliant_dl180_g6_server | - | - | |||||
运行在以下环境 | |||||||||
硬件 | hp | proliant_dl180_gen9_server | - | - | |||||
运行在以下环境 | |||||||||
硬件 | hp | proliant_dl20_gen9_server | - | - | |||||
运行在以下环境 | |||||||||
硬件 | hp | proliant_dl320e_gen8_server | - | - | |||||
运行在以下环境 | |||||||||
硬件 | hp | proliant_dl320e_gen8_v2_server | - | - | |||||
运行在以下环境 | |||||||||
硬件 | hp | proliant_dl320_g6_server | - | - | |||||
运行在以下环境 | |||||||||
硬件 | hp | proliant_dl360e_gen8_server | - | - | |||||
运行在以下环境 | |||||||||
硬件 | hp | proliant_dl360p_gen8_server | - | - | |||||
运行在以下环境 | |||||||||
硬件 | hp | proliant_dl360_g6_server | - | - | |||||
运行在以下环境 | |||||||||
硬件 | hp | proliant_dl360_g7_server | - | - | |||||
运行在以下环境 | |||||||||
硬件 | hp | proliant_dl360_gen9_server | - | - | |||||
运行在以下环境 | |||||||||
硬件 | hp | proliant_dl370_g6_server | - | - | |||||
运行在以下环境 | |||||||||
硬件 | hp | proliant_dl380e_gen8_server | - | - | |||||
运行在以下环境 | |||||||||
硬件 | hp | proliant_dl380p_gen8_server | - | - | |||||
运行在以下环境 | |||||||||
硬件 | hp | proliant_dl380_g6_server | - | - | |||||
运行在以下环境 | |||||||||
硬件 | hp | proliant_dl380_g7_server | - | - | |||||
运行在以下环境 | |||||||||
硬件 | hp | proliant_dl380_gen9_server | - | - | |||||
运行在以下环境 | |||||||||
硬件 | hp | proliant_dl385p_gen8_(amd) | - | - | |||||
运行在以下环境 | |||||||||
硬件 | hp | proliant_dl385_g7_server | - | - | |||||
运行在以下环境 | |||||||||
硬件 | hp | proliant_dl560_gen8_server | - | - | |||||
运行在以下环境 | |||||||||
硬件 | hp | proliant_dl560_gen9_server | - | - | |||||
运行在以下环境 | |||||||||
硬件 | hp | proliant_dl580_g7_server | - | - | |||||
运行在以下环境 | |||||||||
硬件 | hp | proliant_dl580_gen8_server | - | - | |||||
运行在以下环境 | |||||||||
硬件 | hp | proliant_dl585_g7_server_(amd) | - | - | |||||
运行在以下环境 | |||||||||
硬件 | hp | proliant_dl60_gen9_server | - | - | |||||
运行在以下环境 | |||||||||
硬件 | hp | proliant_dl80_gen9_server | - | - | |||||
运行在以下环境 | |||||||||
硬件 | hp | proliant_dl980_g7_server | - | - | |||||
运行在以下环境 | |||||||||
硬件 | hp | proliant_gen6_server | - | - | |||||
运行在以下环境 | |||||||||
硬件 | hp | proliant_gen7_server | - | - | |||||
运行在以下环境 | |||||||||
硬件 | hp | proliant_gen8_server | - | - | |||||
运行在以下环境 | |||||||||
硬件 | hp | proliant_m300_server_cartridge | - | - | |||||
运行在以下环境 | |||||||||
硬件 | hp | proliant_m350_server_cartridge | - | - | |||||
运行在以下环境 | |||||||||
硬件 | hp | proliant_m510_server_cartridge | - | - | |||||
运行在以下环境 | |||||||||
硬件 | hp | proliant_m710p_server_cartridge | - | - | |||||
运行在以下环境 | |||||||||
硬件 | hp | proliant_m710x_server_cartridge | - | - | |||||
运行在以下环境 | |||||||||
硬件 | hp | proliant_m710_server_cartridge | - | - | |||||
运行在以下环境 | |||||||||
硬件 | hp | proliant_microserver_gen8 | - | - | |||||
运行在以下环境 | |||||||||
硬件 | hp | proliant_ml10_gen9_server | - | - | |||||
运行在以下环境 | |||||||||
硬件 | hp | proliant_ml10_v2_server | - | - | |||||
运行在以下环境 | |||||||||
硬件 | hp | proliant_ml110_g6_server | - | - | |||||
运行在以下环境 | |||||||||
硬件 | hp | proliant_ml110_g7_server | - | - | |||||
运行在以下环境 | |||||||||
硬件 | hp | proliant_ml110_gen9_server | - | - | |||||
运行在以下环境 | |||||||||
硬件 | hp | proliant_ml150_g6_server | - | - | |||||
运行在以下环境 | |||||||||
硬件 | hp | proliant_ml150_gen9_server | - | - | |||||
运行在以下环境 | |||||||||
硬件 | hp | proliant_ml30_gen9_server | - | - | |||||
运行在以下环境 | |||||||||
硬件 | hp | proliant_ml310e_gen8_server | - | - | |||||
运行在以下环境 | |||||||||
硬件 | hp | proliant_ml310e_gen8_v2_server | - | - | |||||
运行在以下环境 | |||||||||
硬件 | hp | proliant_ml330_g6_server | - | - | |||||
运行在以下环境 | |||||||||
硬件 | hp | proliant_ml350e_gen8_server | - | - | |||||
运行在以下环境 | |||||||||
硬件 | hp | proliant_ml350e_gen8_v2_server | - | - | |||||
运行在以下环境 | |||||||||
硬件 | hp | proliant_ml350p_gen8_server | - | - | |||||
运行在以下环境 | |||||||||
硬件 | hp | proliant_ml350_g6_server | - | - | |||||
运行在以下环境 | |||||||||
硬件 | hp | proliant_ml350_gen9_server | - | - | |||||
运行在以下环境 | |||||||||
硬件 | hp | proliant_ml370_g6_server | - | - | |||||
运行在以下环境 | |||||||||
硬件 | hp | proliant_sl160s_g6_server | - | - | |||||
运行在以下环境 | |||||||||
硬件 | hp | proliant_sl170z_g6_server | - | - | |||||
运行在以下环境 | |||||||||
硬件 | hp | proliant_sl210t_gen8_server | - | - | |||||
运行在以下环境 | |||||||||
硬件 | hp | proliant_sl250s_gen8_server | - | - | |||||
运行在以下环境 | |||||||||
硬件 | hp | proliant_sl270s_gen8_server | - | - | |||||
运行在以下环境 | |||||||||
硬件 | hp | proliant_sl2x170z_g6_server | - | - | |||||
运行在以下环境 | |||||||||
硬件 | hp | proliant_sl390s_g7_server | - | - | |||||
运行在以下环境 | |||||||||
硬件 | hp | proliant_sl4540_gen8_1_node_server | - | - | |||||
运行在以下环境 | |||||||||
硬件 | hp | proliant_sl4545_g7_server_(amd) | - | - | |||||
运行在以下环境 | |||||||||
硬件 | hp | proliant_thin_micro_tm200_server | - | - | |||||
运行在以下环境 | |||||||||
硬件 | hp | proliant_ws460c_gen9_workstation | - | - | |||||
运行在以下环境 | |||||||||
硬件 | hp | proliant_xl170r_gen9_server | - | - | |||||
运行在以下环境 | |||||||||
硬件 | hp | proliant_xl190r_gen9_server | - | - | |||||
运行在以下环境 | |||||||||
硬件 | hp | proliant_xl230a_gen9_server | - | - | |||||
运行在以下环境 | |||||||||
硬件 | hp | proliant_xl250a_gen9_server | - | - | |||||
运行在以下环境 | |||||||||
硬件 | hp | proliant_xl260a_gen9_server | - | - | |||||
运行在以下环境 | |||||||||
硬件 | hp | proliant_xl270d_gen9_accelerator_tray | - | - | |||||
运行在以下环境 | |||||||||
硬件 | hp | proliant_xl270d_gen9_server | - | - | |||||
运行在以下环境 | |||||||||
硬件 | hp | proliant_xl450_gen9_server | - | - | |||||
运行在以下环境 | |||||||||
硬件 | hp | proliant_xl730f_gen9_server | - | - | |||||
运行在以下环境 | |||||||||
硬件 | hp | proliant_xl740f_gen9_server | - | - | |||||
运行在以下环境 | |||||||||
硬件 | hp | proliant_xl750f_gen9_server | - | - | |||||
- 攻击路径 本地
- 攻击复杂度 低
- 权限要求 低
- 影响范围 未更改
- 用户交互 无
- 可用性 无
- 保密性 高
- 完整性 无
还没有评论,来说两句吧...